Skip Navigation

IEICE Transactions on Information and Systems 2007 E90-D(5):808-815; doi:10.1093/ietisy/e90-d.5.808
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Request Permissions
Google Scholar
Right arrow Articles by TAKI, H.
Right arrow Articles by SATO, T.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2007 The Institute of Electronics, Information and Communication Engineers

Regular Section -- Papers -- Rehabilitation Engineering and Assistive Technology

Transfer Information Enhancement with a 2-D Tactile Stimulator Array for an Acoustic Vision Substitute System

Hirofumi TAKI1 and Toru SATO1

1 The authors are with the Department of Communications and Computer Engineering, Graduate School of Informatics, Kyoto University, Kyoto-shi, 606–8501 Japan. E-mail: taki{at}aso.cce.i.kyoto-u.ac.jp


   Abstract

Existing vision substitute systems have insufficient spatial resolution to provide environmental information. To present detailed spatial information, we propose two stimulation methods to enhance transfer information using a 2-D tactile stimulator array. First, stimulators are divided into several groups. Since each stimulator group is activated alternately, the interval of stimulations can be shortened to less than the two-point discrimination threshold. In the case that stimulators are divided into two and four groups, the number of stimulators increases to twice and four times, respectively, that in the case of the two-point discrimination threshold. Further, a user selects the measurement range and the system presents targets within the range. The user acquires spatial information of the entire measurement area by changing the measurement range. This method can accurately present a range of targets. We examine and confirm these methods experimentally.

Key Words: vision substitute system, tactile, acoustic, hybrid method, human interface


Manuscript received July 24, 2006. Manuscript revised December 14, 2006.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.